HomeMy WebLinkAboutOrdinance No. 3948 Adopting 2024 International Exisiting Building CodeORDINANCE NO. 3948
0-�
AN ORDINANCE OF THE CITY OF FARMERS BRANCH, TEXAS,
AMENDING CHAPTER 22 (BUILDINGS AND BUILDING
REGULATIONS) BY ADDING ARTICLE VII.6 (EXISTING BUILDING
FARMERS CODE); AND ADOPTING THE 2024 EDITION OF THE
BRANCH INTERNATIONAL EXISTING BUILDING CODE, WITH CERTAIN
ADDITIONS, DELETIONS, AND AMENDMENTS, AS THE EXISTING
BUILDING CODE OF THE CITY OF FARMERS BRANCH; PROVIDING
A SEVERABILITY CLAUSE, A SAVINGS CLAUSE, A PENALTY
CLAUSE; AND PROVIDING AN EFFECTIVE DATE.
WHEREAS, the International Code Council (ICC) has developed a set of comprehensive
and coordinated national model construction codes, including the International Existing Building
Code; and
WHEREAS, since the 1970s, the City of Farmers Branch has been involved throughout
the development process of the ICC, specifically the International Existing Building Code, in
conjunction with the North Texas Chapter of the International Code Council, Regional Codes
Coordinating Committee of North Central Texas Council of Governments (NCTCOG), and the
International Conference of Building Officials (ICBG); and
WHEREAS, the 2024 International Existing Building Code, a publication of the ICC, has
been reviewed by city staff and the NCTCOG for necessary updates and amendments; and
WHEREAS, the City Council of the City of Farmers Branch has determined that it is in
the best interest of the citizens of the City of Farmers Branch to adopt the 2024 Edition of the
International Existing Building Code, and the additions, deletions, and amendments thereto, as the
minimum standards for the safe repair, alteration, addition and change of occupancy of existing
buildings and structures within the City limits, as set forth herein, and to adopt the Existing
Building Code in order to account for unique local practices and /or conditions within the City;
NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF
FARMERS BRANCH, TEXAS, THAT:
SECTION 1. A new Chapter 22 (Buildings and Building Regulations) Article VII.6 (Existing
Building Code) is hereby adopted and shall read in its entirety as follows:
ARTICLE VII.6. EXISTING BUILDING CODE
Sec. 22 - 235. Adoption of International Existing Building Code; purpose.
The 2024 Edition of the International Existing Building Code, as published by the
International Code Council and as amended pursuant to Sec. 22-235 is hereby
adopted. Copies of the Existing Building Code are on file in the office of the city
secretary for permanent record and inspection and are incorporated into this section
as if fully set forth herein. The city manager or designee, is hereby authorized and
directed to enforce all provisions of the Mechanical Code. For purposes of this
Article, the phrase "Existing Building Code" means collectively (i) the 2024
Edition international Existing Building Code, as published by the International
Code Council and (ii) the local amendments adopted pursuant to Sec. 22-236.
Sec 22-236. Local Amendments to the International Existing Building Code:
For purposes of enforcement of the provisions of the Mechanical Code within the
incorporated limits of the City, the following deletions, additions, and amendments
to the 2024 Edition of the International Existing Building Code are hereby approved
and amended as follows:
Section 102.4; change to read as follows:
[A] 102.4 Referenced codes and standards. The codes, when specifically adopted,
and standards referenced in this code shall be considered part of the requirements
of this code to the prescribed extent of each such reference and as further regulated
in Sections 102.4.1 and 102.4.2. {No change to rest of section.)
Section 102.4.3 add to read as follows:
102.4.3 Electrical. The provisions of the local adopted Electrical Code shall apply
to the installation of electrical systems, including alterations, repairs, replacement,
equipment, appliances, fixtures, fittings and appurtenances thereto.
Section 104.2.4.1 Flood hazard areas. (Jurisdictions may consider the option to
amend or delete depending on local enforcement and flood hazard ordinances.)
Section 104.3.1 Determination of substantially improved or substantially
damaged existing buildings and structures in flood hazard areas. (Jurisdictions
may consider the option to amend or delete depending on local enforcement and
flood hazard ordinances.)
Section 202; amend definition of Existing Building as follows:
Existing Building - A building, structure, or space with an approved final inspection
issued under a code edition which is at least 2 published code editions preceding
the currently adopted building code; a building, structure or space that is undergoing
a change of occupancy or use.
Section 302.2 Additional Codes; Amend to read as follows:
302.2: Additional Codes
Alterations, repairs, additions and changes of occupancy to, or relocation of, existing
buildings and structures shall comply with the provisions for alterations, repairs,
684
additions and changes of occupancy or relocation, respectively, in this code and the
International Energy Conservation Code , International Fire Code, International
Fuel Gas Code, International Mechanical Code, International Plumbing Code,
International Private Sewage Disposal Code, International Property Maintenance
Code, International Residential Code and NFPA 70 and any other Codes or other
ordinances adopted by the authority having jurisdiction. Where provisions of the
other codes conflict with provisions of this code, the provisions of this code shall
take precedence.
Section 306.1 Scope; add exceptions to read as follows:
Exceptions:
1. Components of projects regulated by and registered with Architectural
Barriers Division of Texas Department of Licensing and Regulation shall be
deemed to be in compliance with the requirements of this chapter.
Section 309.2.1 Automatic sprinkler systems; Delete this section
Section 401.3 Flood Hazard Areas; Delete this section.
Section 405.2.6 Flood Hazard Areas; Delete this section.
Section 502.2 Flood Hazard Areas; Delete this section.
Section 503.2 Flood Hazard Areas; Delete this section.
Section 503.18 Enhanced classroom acoustics; add after paragraph to read as
follows:
Compliance with the Texas Accessibility Standards is not considered equivalent
compliance for the purpose of enforcement of this code section.
Section 504.1.2; change to read as follows:
504.1.2 Existing fire escapes. Existing fire escapes shall continue to be accepted as
a component in the means of egress in existing buildings only. Existing fire escapes
shall be permitted to be repaired or replaced.
Section 504.1.3; Delete this section:
Section 507.3 Flood Hazard Areas; Delete this section.
685
Section 701.3 Flood Hazard Areas; Delete this section.
Section 702.7; add a code reference to read as follows:
702.7 Materials and methods. All new work shall comply with the materials and
methods requirements in the International Building Code, International Energy
Conservation Code, International Mechanical Code, National Electrical Code, and
International Plumbing Code, as applicable, that specify material standards, detail
of installation and connection, joints, penetrations, and continuity of any element,
component, or system in the building.
Section 802.5.1; change to read as follows
802.5.1 Minimum requirement. Every portion of open -sided walking surfaces,
including mezzanines, equipment platforms, aisles, stairs, ramps, and landings that
is more than 30 inches (762 mm) above the floor or grade below and is not provided
with guards, or those in which the existing guards are judged to be in danger of
collapsing, shall be provided with guards.
Section 803.1 Scope; add sentence to read as follows:
For the purpose of fire sprinkler protection and fire alarm requirements included in
this section, the work area shall be extended to include at least the entire tenant
space or spaces bounded by walls capable of resisting the passage of smoke
containing the subject work area, and if the work area includes a corridor, hallway,
or other exit access, then such corridor, hallway, or other exit access shall be
protected in its entirety on that particular floor level.
Section 803.3; change section to read as follows:
803.3 Standpipes. Refer to Section 1103.6 of the Fire Code for retroactive standpipe
requirements.
{Delete rest of Section 803.3.}
Section 804.2 General; delete Exception #1 as follows:
Exceptions:
1. delete
2. [Remain unchanged]
Section 804.5.1.2.; change to read as follows:
804.5.1.2 Fire Escapes required. For other than Group I-2, where more than one
exit is required, an existing fire escape complying with section 805.3.1.2.1 shall be
686
accepted as providing one of the required means of egress.
Section 804.5.1.2.1; change to read as follows:
804.5.1.2.1 Fire Escape access and details - ...
1. [Remain unchanged]
2. Access to a Mire escape shall be through a door... [remainder unchanged]
3. [Remain unchanged]
5. In all buildings of Group E occupancy up to and including the 12th grade,
buildings of Group I occupancy, boarding houses, and childcare centers, ladders of
any type are prohibited on fire escapes used as a required means of egress.
Section 804.7.2 Transoms; amend to read as follows:
804.7.2 Transoms. In all buildings of Group B, E, I-1, I-2, R-1 and R-2
occupancies, ....[Remainder unchanged]
Section 904.1 Automatic sprinkler systems; add sentence to read as follows:
For the purpose of fire sprinkler protection and fire alarm requirements included in
this section, the work area shall be extended to include at least the entire tenant
space or spaces bounded by walls containing the subject work area, and if the work
area includes a corridor, hallway, or other exit access, then such corridor, hallway,
or other exit access shall be protected in its entirety on that particular floor level.
Section 904.1.1; change to read as follows:
904.1.1 High-rise buildings. An automatic sprinkler system shall be provided in
work areas of high-rise buildings.
Section 1011.2.1: change to read as follows:
1011.2.1 Automatic Fire sprinkler system. The installation of an automatic
sprinkler system shall be required where there is a change of occupancy
classification and Chapter 9 of the current International Building Code requires an
automatic sprinkler system based on the new occupancy or where there is a change
of occupancy within the space where there is a different fire protection system
threshold requirement in Chapter 9 of the current International Building Code than
exists in the current building or space. The installation of the automatic sprinkler
system shall be required within the area of the change of occupancy and areas of
the building not separated horizontally and vertically from the change of occupancy
by a fire barrier or fire wall.
Section 1103.3 Flood Hazard Areas; Delete this section.
687
Section 1201.4 Flood Hazard Areas; Delete this section.
Section 1303.1.2; change to read as follows:
1301.3.2 Compliance with other codes. Buildings that are evaluated in accordance
with this section shall comply with the International Fire Code.
Section 1303.1.3 Compliance with Flood Hazard Provisions; Delete this section.
Section 1402.6 Flood Hazard Areas; Delete this section.
[F] Section 1502.1 Site safety plan; change to read
[Existing text remains]
The plan shall be submitted and approved by the Fire Department before a building
permit is issued, [Remainder of Existing text remains]
[F] Section 1502.3.1 Violations; change to read
Failure to properly conduct, document and maintain documentation required by this
section shall constitute an unlawful act in accordance with Section 113.1 and shall
result in the issuance of a notice of violation, by the Fire code official, to the site
safety director. Upon the third offense, the Fire code official, based on their
findings, shall request a stop work order enforcement be implemented to the code
official in accordance with Section 114, and work shall not resume until satisfactory
assurances of future compliance have been presented to and approved by the code
official.
Section 1512.1 When Required; Delete Section 1512.1 through 1512.5 and
change Section 1512.1 to read as follows:
1512.1 When required. An approved water supply for fire protection, either
temporary or permanent, shall be made available as soon as combustible material
arrives on the site or as determined by the code official. The water supply design
and the timing of the water supply installation relative to building construction shall
comply with the adopted Fire Code.
Sec. 22 -237 — 22-239. - Reserved.
SECTION 2. It is the intention of the City Council that this Ordinance, and every provision
thereof, shall be considered severable, and the invalidity or unconstitutionality of any section,
688
clause, provision, or portion of this Ordinance shall not affect the validity or constitutionality of
any other portion of this Ordinance.
SECTION 3. The repeal of any Ordinance or part of Ordinances effectuated by the enactment of
this Ordinance shall not be construed as abandoning any action now pending under or by virtue of
such Ordinance or as discontinuing, abating, modifying or altering any penalty accruing or to
accrue, or as affecting any rights of the municipality under any section or provisions of any
Ordinances at the time of passage of this Ordinance.
SECTION 4. Any violation of the provisions or terms of this ordinance shall be subject to the
same penalty as provided in the Code of Ordinances of the City of Farmers Branch as heretofore
amended and, upon conviction, shall be punished by a fine not to exceed the sum of Two Thousand
Dollars ($2,000.00). Every day a violation continues shall constitute a separate offense.
SECTION 5. This Ordinance shall take effect on October 1, 2025, following the passage
of this Ordinance, the publication of the caption hereof as the law and charter in such case
provide.
PASSED AND APPROVED BY THE CITY COUNCIL OF THE CITY OF FARMERS
BRANCH, TEXAS, THIS 19th DAY OF AUGUST, 2025.
ATTEST:
Erin Flores, City Secretary
APPROVED AS TO FORM:
Nicole Corr, City Attorney
1vf.07.20.251
APPR D:
Terry Ly e, Aayor
689